1/4/2024 0 Comments Install4j smartscreenRevised the trace plotting order on some of the graphs.A phase column is not included in text exports if the measurement does not have phase data.When removing delay from soundcard calibration measurements round to the nearest sample, sub-sample delay estimates on soundcard responses tend to be slightly in error due to the reconstruction and antialias filters.Show a warning if the ASIO driver sample rate is not the rate that was requested.Added an option in the All SPL graph Align SPL dialog to use the average dB SPL of the selected measurements as the target.Level meters panel is resizeable in width and height.Added an option to switch orientation in the the level meters right click popup menu.Moved the relative gain and phase panel from below the level meters into its own frame, accessed via the Tools menu.Added Ctrl+Alt+M shortcut to show the new Generate minimum phase dialog.Low and high frequency tails can be added to responses for minimum phase generation.responses imported from text files), it creates or replaces the phase response with the minimum phase response and gives the measurement a minimum phase impulse response Minimum phase can be generated for measurements which do not have an impulse response (e.g.Generating minimum phase may now include the effects of any calibration files in the magnitude response used to produce the minimum phase.The RTA input selection dialog is no longer modal.Text exports of multi-input capture measurements can optionally include each input as well as the average.Multi-input RTA measurements are saved in the same multi-input average format as sweep measurements, showing the span of the individual inputs as an underlay.In multi-input capture mode the level meters can show the first 16 inputs being captured.In multi-input capture mode the RTA can show the first 16 inputs being captured in addition to their rms average. Added a button in the SPL & Phase graph controls to adjust the SPL alignment and weighting of multi-input capture measurements.Added a button on the RTA input selection dialog to configure the SPL alignment and weighting of multi-input captures.Added a button on the Measure dialog to configure the SPL alignment and weighting of multi-input capture measurements.macOS: Fixed colours in dark mode for the file chooser and some other components.Bug fix: Trying to average RTA measurements would produce an out of memory error.Bug fix: Decay graph would generate an exception if the slice interval was more than the window length in CSD mode.Limit the series R for capacitor component model fits to 1 ohm maximum for caps below 100 nF.Adjusted threshold for using more compact layouts so it is used for display height (or scaled height) of 720 pixels or less. The delay figure for the acoustic timing reference always uses the estimated IR delay/estimated IR start.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |